Resultados 1 - 20 de 16.081
Filtrar
2.
Sci Rep ; 14(1): 7621, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561413

RESUMO

The association between the initial cardiac rhythm and short-term survival in patients with in-hospital cardiac arrest (IHCA) has not been extensively studied despite the fact that it is thought to be a prognostic factor in patients with out-of-hospital cardiac arrest. This study aimed to look at the relationship between initial shockable rhythm and survival to hospital discharge in individuals with IHCA. 1516 adults with IHCA who received chest compressions lasting at least two minutes at the National Taiwan University Hospital between 2006 and 2014 made up the study population. Propensity scores were estimated using a fitted multivariate logistic regression model. Various statistical methodologies were employed to investigate the association between shockable rhythm and the probability of survival to discharge in patients experiencing IHCA, including multivariate adjustment, propensity score adjustment, propensity score matching, and logistic regression based on propensity score weighting. In the original cohort, the multivariate-adjusted odds ratio (OR) was 2.312 (95% confidence interval [CI]: 1.515-3.531, P < 0.001). In additional propensity score adjustment, the OR between shockable rhythm and the probability of survival to hospital discharge in IHCA patients was 2.282 (95% CI: 1.486, 3.504, P < 0.001). The multivariate-adjusted logistic regression model analysis revealed that patients with shockable rhythm had a 1.761-fold higher likelihood of surviving to hospital release in the propensity score-matched cohort (OR = 2.761, 95% CI: 1.084-7.028, P = 0.033). The multivariate-adjusted OR of the inverse probability for the treatment-weighted cohort was 1.901 (95% CI: 1.507-2.397, P < 0.001), and the standardized mortality ratio-weighted cohort was 2.692 (95% CI: 1.511-4.795, P < 0.001). In patients with in-hospital cardiac arrest, Initial cardiac rhythm is an independent predictor of survival to hospital discharge. Depending on various statistical methods, patients with IHCA who have a shockable rhythm have a one to two fold higher probability of survival to discharge than those who have a non-shockable rhythm. This provides a reference for optimizing resuscitation decisions for IHCA patients and facilitating clinical communication.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Adulto , Humanos , Reanimação Cardiopulmonar/métodos , Pontuação de Propensão , Cardioversão Elétrica/métodos , Parada Cardíaca Extra-Hospitalar/terapia , Hospitais , Sistema de Registros
3.
J Cardiothorac Surg ; 19(1): 167, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561765

RESUMO

BACKGROUND: The implantation of left ventricular assist devices (LVADs) as a bridge to transplantation or as destination therapy in end-stage heart failure patients is frequently complicated by the emergence of ventricular arrhythmias (VAs). These arrhythmias have been implicated in precipitating deleterious clinical outcomes, increased mortality rates and augmented healthcare expenditures. CASE PRESENTATION: We present a challenging case of a 49-year-old male with a history of dilated cardiomyopathy who received an LVAD. Post-implantation, the patient suffered from intractable VAs, leading to multiple rehospitalizations and hemodynamic deterioration. Despite exhaustive medical management and electrical cardioversion attempts, the patient's VAs persisted, ultimately necessitating prioritization for cardiac transplantation. DISCUSSION: This case highlights the challenges in managing VAs in LVAD patients and the importance of multidisciplinary collaboration. While pharmacological intervention is the initial strategy, catheter ablation may be considered in selected cases when medication is insufficient. In instances of intractable VAs, expeditious listing for heart transplantation as a high-priority candidate is advisable when feasible.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Masculino , Humanos , Pessoa de Meia-Idade , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Arritmias Cardíacas/etiologia , Hemodinâmica , Cardioversão Elétrica , Resultado do Tratamento
4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Resultado do Tratamento , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
5.
BMJ Open ; 14(4): e083692, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589259

RESUMO

OBJECTIVES: To analyse monthly changes in public access defibrillation (PAD) incidence and outcomes of out-of-hospital cardiac arrest (OHCA) during the 2020-2021 COVID-19 pandemic compared with those during the 2016-2019 prepandemic period with consideration of pandemic-related movement restriction. DESIGN: Retrospective cohort study. SETTING: An extended database was created by combining and reconciling the nationwide Utstein-style OHCA and the emergency medical service (EMS) transportation databases in Japan. PARTICIPANTS: We analysed 226 182 EMS-witnessed, non-newborn and out-of-home OHCA cases in Japan. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcomes were the PAD incidence and neurologically favourable 1-month survival rate. The secondary outcomes were bystander cardiopulmonary resuscitation (CPR) provision and dispatcher-assisted CPR attempts. RESULTS: The proportion of out-of-home OHCA cases slightly decreased during the pandemic (from 33.7% to 31.9%). Although the pandemic was associated with a decreased PAD incidence, 2-year trend analyses by an interaction test showed that the PAD incidence was lower during the first nationwide declaration of a state of emergency (p<0.001) and in the pandemic's second year (p<0.01). Regardless of location, delays in basic life support (BLS) actions and EMS contact with patients were more common and the rate of PAD-induced return of spontaneous circulation was lower during the pandemic. PAD incidence reduction was significant only in locations with a recommendation of automated external defibrillator placement (p<0.001). In other locations, a pronounced delay in BLS was found during the pandemic. The neurologically favourable survival rate was reduced in parallel with the reduced PAD incidence during the pandemic (r=0.612, p=0.002). CONCLUSIONS: Prolonged and repeated movement restrictions during the COVID-19 pandemic worsened the OHCA outcomes concurrently with disturbed BLS actions, including the reduced PAD incidence in out-of-home settings. Maintaining BLS training, re-arranging automated external defibrillator placement and establishing a local alert system for recruiting well-trained citizens to the scene are essential.


Assuntos
COVID-19 , Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Humanos , Cardioversão Elétrica , Pandemias , Estudos Retrospectivos , Japão/epidemiologia , Sistema de Registros , Parada Cardíaca Extra-Hospitalar/epidemiologia , Parada Cardíaca Extra-Hospitalar/terapia , Parada Cardíaca Extra-Hospitalar/complicações , COVID-19/epidemiologia , COVID-19/terapia , COVID-19/complicações
6.
BMC Cardiovasc Disord ; 24(1): 213, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632510

RESUMO

BACKGROUND: Atrial fibrillation is the most prevalent sustained cardiac arrhythmia. Electrical cardioversion, a well-established part of the rhythm control strategy, is probably underused in community settings. Here, we describe its use, safety, and effectiveness in a cohort of patients with atrial fibrillation treated in rural settings. METHODS: It is a retrospective cohort study. Data on all procedures from January 1, 2016, till December 1, 2022, in Tarusa Hospital, serving mostly a rural population of 15,000 people, were extracted from electronic health records. Data on the procedure's success, age, gender, body mass index, comorbidities, previous procedures, echocardiographic parameters, type and duration of arrhythmia, anticoagulation, antiarrhythmic drugs, transesophageal echocardiography, and settings were available. RESULTS: Altogether, 1,272 procedures in 435 patients were performed during the study period. The overall effectiveness of the procedure was 92%. Effectiveness was similar across all prespecified subgroups. Electrical cardioversion was less effective in patients undergoing the procedure for the first time (86%, 95% CI: 82-90) compared to repeated procedures (95%, 95% CI: 93-96), OR 0.39 (95% CI: 0.26-0.59). Complications were encountered in 13 (1.02%) procedures but were not serious. CONCLUSIONS: Electrical cardioversion is an immediately effective procedure that can be safely performed in community hospitals, both in inpatient and outpatient settings. Further studies with longer follow-up are needed to investigate the rate of sinus rhythm maintenance in these patients.


Assuntos
Fibrilação Atrial , Humanos , Cardioversão Elétrica , Estudos Retrospectivos , Hospitais Comunitários , Resultado do Tratamento
7.
Circ Cardiovasc Qual Outcomes ; 17(4): e010061, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38529632

RESUMO

BACKGROUND: Drone-delivered automated external defibrillators (AEDs) hold promises in the treatment of out-of-hospital cardiac arrest. Our objective was to estimate the time needed to perform resuscitation with a drone-delivered AED and to measure cardiopulmonary resuscitation (CPR) quality. METHODS: Mock out-of-hospital cardiac arrest simulations that included a 9-1-1 call, CPR, and drone-delivered AED were conducted. Each simulation was timed and video-recorded. CPR performance metrics were recorded by a Laerdal Resusci Anne Quality Feedback System. Multivariable regression modeling examined factors associated with time from 9-1-1 call to AED shock and CPR quality metrics (compression rate, depth, recoil, and chest compression fraction). Comparisons were made among those with recent CPR training (≤2 years) versus no recent (>2 years) or prior CPR training. RESULTS: We recruited 51 research participants between September 2019 and March 2020. The median age was 34 (Q1-Q3, 23-54) years, 56.9% were female, and 41.2% had recent CPR training. The median time from 9-1-1 call to initiation of CPR was 1:19 (Q1-Q3, 1:06-1:26) minutes. A median time of 1:59 (Q1-Q3, 01:50-02:20) minutes was needed to retrieve a drone-delivered AED and deliver a shock. The median CPR compression rate was 115 (Q1-Q3, 109-124) beats per minute, the correct compression depth percentage was 92% (Q1-Q3, 25-98), and the chest compression fraction was 46.7% (Q1-Q3, 39.9%-50.6%). Recent CPR training was not associated with CPR quality or time from 9-1-1 call to AED shock. Younger age (per 10-year increase; ß, 9.97 [95% CI, 4.63-15.31] s; P<0.001) and prior experience with AED (ß, -30.0 [95% CI, -50.1 to -10.0] s; P=0.004) were associated with more rapid time from 9-1-1 call to AED shock. Prior AED use (ß, 6.71 [95% CI, 1.62-11.79]; P=0.011) was associated with improved chest compression fraction percentage. CONCLUSION: Research participants were able to rapidly retrieve an AED from a drone while largely maintaining CPR quality according to American Heart Association guidelines. Chest compression fraction was lower than expected.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Humanos , Feminino , Adulto , Masculino , Parada Cardíaca Extra-Hospitalar/diagnóstico , Parada Cardíaca Extra-Hospitalar/terapia , Dispositivos Aéreos não Tripulados , Cardioversão Elétrica/efeitos adversos , Desfibriladores
8.
Medicina (Kaunas) ; 60(3)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38541236

RESUMO

Out-of-hospital cardiac arrest (OHCA) is heterogeneous in terms of etiology and severity. Owing to this heterogeneity, differences in outcome and treatment efficacy have been reported from case to case; however, few reviews have focused on the heterogeneity of OHCA. We conducted a literature review to identify differences in the prognosis and treatment efficacy in terms of CA-related waveforms (shockable or non-shockable), age (adult or pediatric), and post-CA syndrome severity and to determine the preferred treatment for patients with OHCA to improve outcomes.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Adulto , Humanos , Criança , Reanimação Cardiopulmonar/efeitos adversos , Parada Cardíaca Extra-Hospitalar/etiologia , Parada Cardíaca Extra-Hospitalar/terapia , Resultado do Tratamento , Cardioversão Elétrica/efeitos adversos , Prognóstico , Sistema de Registros
9.
Pacing Clin Electrophysiol ; 47(4): 496-502, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38462721

RESUMO

BACKGROUND: Inappropriate shock (IAS) caused by subcutaneous air entrapment (AE) in an early period after subcutaneous implantable cardioverter defibrillator (S-ICD) implantation has been reported, however, no detailed data on air volume are available. We evaluated the subcutaneous air volume after implantation and its absorption rate one week after implantation. METHODS: Patients who underwent S-ICD implantation in our hospital received chest CT scans immediately after implantation and followed up 1 week later. The total subcutaneous air volume, air around the generator, the distal electrode, and the proximal electrode within 3 cm were calculated using a three-dimensional workstation. Fat areas at the level of the lower edge of the generator were also analyzed. RESULT: Fifteen patients received CT immediately after implantation. The mean age was 45.6 ± 17.9 (66.7% of men), and the mean body mass index was 24.3 ± 3.3. The three-incision technique was applied in seven patients and two-incision technique was in the latter eight patients. The mean total subcutaneous air volume was 18.54 ± 7.50 mL. Air volume around the generator, the distal electrode, and the proximal electrode were 11.05 ± 5.12, 0.72 ± 0.72, and 0.88 ± 0.87 mL, respectively. Twelve patients received a follow-up CT 1 week later. The mean total subcutaneous air was 0.25 ± 0.45 mL, showing a 98.7% absorption rate. CONCLUSION: Although subcutaneous air was observed in all patients after S-ICD implantation, most of the air was absorbed within 1 week, suggesting a low occurrence of AE-related IAS after a week postoperation.


Assuntos
Desfibriladores Implantáveis , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Tomografia Computadorizada por Raios X , Tomografia , Resultado do Tratamento
11.
Open Heart ; 11(1)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38458770

RESUMO

The wearable cardioverter defibrillator (WCD) is becoming a more and more widely used instrument for the prevention of sudden cardiac death of patients either with a secondary prevention implantable cardioverter defibrillator indication or with a transient high risk of sudden cardiac death. Although clinical practice has demonstrated a benefit of protecting patients for a period as long as 3-6 months with such devices, the current European guidelines concerning ventricular arrhythmias and sudden cardiac death are still extremely restrictive in the patient selection in part because of the costs derived from such a prevention device, in part because of the lack of robust randomised trials.To illustrate expanded use cases for the WCD, four real-life clinical cases are presented where patients received the device slightly outside the established guidelines. These cases demonstrate the broader utility of WCDs in situations involving acute myocarditis, thyrotoxicosis, pre-excited atrial fibrillation and awaiting staging/prognosis of a lung tumour. The findings prompt expansion of the existing guidelines for WCD use to efficiently protect more patients whose risk of arrhythmic cardiac death is transient or uncertain. This could be achieved by establishing a European register of the patients who receive a WCD for further analysis.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Humanos , Cardioversão Elétrica/efeitos adversos , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fibrilação Atrial/complicações
12.
JAMA ; 331(7): 601-610, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38497695

RESUMO

Importance: Paroxysmal supraventricular tachycardia (PSVT), defined as tachyarrhythmias that originate from or conduct through the atria or atrioventricular node with abrupt onset, affects 168 to 332 per 100 000 individuals. Untreated PSVT is associated with adverse outcomes including high symptom burden and tachycardia-mediated cardiomyopathy. Observations: Approximately 50% of patients with PSVT are aged 45 to 64 years and 67.5% are female. Most common symptoms include palpitations (86%), chest discomfort (47%), and dyspnea (38%). Patients may rarely develop tachycardia-mediated cardiomyopathy (1%) due to PSVT. Diagnosis is made on electrocardiogram during an arrhythmic event or using ambulatory monitoring. First-line acute therapy for hemodynamically stable patients includes vagal maneuvers such as the modified Valsalva maneuver (43% effective) and intravenous adenosine (91% effective). Emergent cardioversion is recommended for patients who are hemodynamically unstable. Catheter ablation is safe, highly effective, and recommended as first-line therapy to prevent recurrence of PSVT. Meta-analysis of observational studies shows single catheter ablation procedure success rates of 94.3% to 98.5%. Evidence is limited for the effectiveness of long-term pharmacotherapy to prevent PSVT. Nonetheless, guidelines recommend therapies including calcium channel blockers, ß-blockers, and antiarrhythmic agents as management options. Conclusion and Relevance: Paroxysmal SVT affects both adult and pediatric populations and is generally a benign condition. Catheter ablation is the most effective therapy to prevent recurrent PSVT. Pharmacotherapy is an important component of acute and long-term management of PSVT.


Assuntos
Taquicardia Ventricular , Adulto , Criança , Feminino , Humanos , Masculino , Adenosina/administração & dosagem , Adenosina/uso terapêutico , Administração Intravenosa , Antiarrítmicos/administração & dosagem , Antiarrítmicos/uso terapêutico , Cardiomiopatias/etiologia , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Ablação por Cateter , Eletrocardiografia , Manobra de Valsalva , Cardioversão Elétrica
16.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38533836

RESUMO

AIMS: In the current guidelines, smartphone photoplethysmography (PPG) is not recommended for diagnosis of atrial fibrillation (AF), without a confirmatory electrocardiogram (ECG) recording. Previous validation studies have been performed under supervision in healthcare settings, with limited generalizability of the results. We aim to investigate the diagnostic performance of a smartphone-PPG method in a real-world setting, with ambulatory unsupervised smartphone-PPG recordings, compared with simultaneous ECG recordings and including patients with atrial flutter (AFL). METHODS AND RESULTS: Unselected patients undergoing direct current cardioversion for treatment of AF or AFL were asked to perform 1-min heart rhythm recordings post-treatment, at least twice daily for 30 days at home, using an iPhone 7 smartphone running the CORAI Heart Monitor PPG application simultaneously with a single-lead ECG recording (KardiaMobile). Photoplethysmography and ECG recordings were read independently by two experienced readers. In total, 280 patients recorded 18 005 simultaneous PPG and ECG recordings. Sufficient quality for diagnosis was seen in 96.9% (PPG) vs. 95.1% (ECG) of the recordings (P < 0.001). Manual reading of the PPG recordings, compared with manually interpreted ECG recordings, had a sensitivity, specificity, and overall accuracy of 97.7%, 99.4%, and 98.9% with AFL recordings included and 99.0%, 99.7%, and 99.5%, respectively, with AFL recordings excluded. CONCLUSION: A novel smartphone-PPG method can be used by patients unsupervised at home to achieve accurate heart rhythm diagnostics of AF and AFL with very high sensitivity and specificity. This smartphone-PPG device can be used as an independent heart rhythm diagnostic device following cardioversion, without the requirement of confirmation with ECG.


Assuntos
Fibrilação Atrial , Flutter Atrial , Humanos , Smartphone , Fibrilação Atrial/diagnóstico , Eletrocardiografia/métodos , Flutter Atrial/diagnóstico , Cardioversão Elétrica , Fotopletismografia
17.
Am J Cardiol ; 218: 77-85, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38458580

RESUMO

Left atrial or left atrial appendage thrombosis (LAT) is contraindicated for cardiac ablation (CA) or cardioversion (CV) of atrial fibrillation (AF). This study was aimed to compare the frequency of LAT detected by transesophageal echocardiography (TEE) before CA or CV in patients with AF treated with direct oral anticoagulants (DOACs) or vitamin K antagonists (VKAs). We searched PubMed, Scopus, Web of Science, and Cochran Library databases from inception through July 13, 2023 to select studies reporting data on LAT identification before CA or CV using TEE in patients with AF treated with DOACs or VKAs. Pooled odds ratios (ORs) with 95% confidence interval were calculated with a random-effects model. Studies retrieved were 50 (38 observational), 29 on CA, 15 on CV, and 6 on both procedures (17,096 patients on DOACs and 13,666 on VKAs). The overall prevalence of LAT was smaller in DOACs than in VKAs, with an OR of 0.66 (0.52 to 0.84), confirmed at sensitivity analysis and in most subgroups. This finding was consistent for the 3 most reported DOACs: the pooled OR for LAT was 0.68 (0.50 to 0.90) in apixaban, 0.67 (0.51 to 0.88) in dabigatran, 0.61 (0.43 to 0.89) in rivaroxaban, and 1.10 (0.74 to 1.64) in edoxaban (not significant). In conclusion, in this large meta-analysis in patients with AF, the prevalence of LAT by TEE evaluation performed before CV or CA appears lower in those treated with DOACs than in those on VKAs. Additional research may help in better understanding differences between these classes of anticoagulant drugs in the setting of protection against AF-related left atrial thrombotic formation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Fibrilação Atrial/epidemiologia , Cardioversão Elétrica , Prevalência , Anticoagulantes/uso terapêutico , Trombose/prevenção & controle , Cardiopatias/tratamento farmacológico , Vitamina K , Administração Oral , Acidente Vascular Cerebral/prevenção & controle
18.
Pacing Clin Electrophysiol ; 47(3): 392-397, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38341633

RESUMO

BACKGROUND: Routine defibrillation threshold testing (DFT) of transvenous implantable defibrillators (ICDs) has largely been in decline. In patients with non-transvenous ICDs that utilize subcutaneous and pleural ICD leads, serial DFT testing can detect a significant number of failures. Data about the utility of follow-up defibrillation safety margin testing (DSM) testing in pediatric patients and young adults with an epicardial ICD are lacking. METHODS: Patients aged < 25 years old who underwent epicardial ICD placement at Mayo Clinic from 2014 to 2023 with at least one follow-up DSM test were included. The patients were divided into a "routine" (R) and "clinically indicated" (CI) group based on the index of clinical concern. Inadequate DSM was defined as unsuccessful defibrillation at an output of less than 10 J below the maximum output of the device. The purpose of this study was to assess the utility of follow-up DSM testing. RESULTS: An epicardial ICD system was placed in 122 patients. A total of 26 patients met inclusion criteria and underwent a total of 47 DSM follow up tests. Inadequate DSM occurred in 1/33 (3%) in the R group and 2/14 (14%) DSM tests in the CI group. The median follow-up period was 54 and 36 months for the R and CI group, respectively. CONCLUSIONS: Our data suggest that epicardial ICDs are reliable and routine follow-up DSM testing may not be necessary for all patients. DSM testing should be performed in individuals with epicardial ICD systems when there is clinical concern about lead or coil performance.


Assuntos
Desfibriladores Implantáveis , Humanos , Criança , Adulto , Seguimentos , Cardioversão Elétrica , Desenho de Equipamento
19.
Can Vet J ; 65(2): 115-118, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38304475

RESUMO

The occurrence of right-sided congestive heart failure (CHF) in dogs with left-sided heart disease is well-recognized, but its mechanisms are incompletely understood. A 12-year-old Maltese dog was admitted to the clinic for left atrial decompression to treat recurrent CHF due to severe myxomatous mitral valve disease (MMVD). Left atrial decompression was successful but atrial fibrillation (AF) occurred during the procedure. Electric cardioversion restored normal sinus rhythm (NSR) and the dog's recovery was uneventful. This sequence of events made it possible to study intracameral pressures individually in each atrium in a dog with naturally occurring MMVD during AF and again during NSR. Although pressures in both atria declined following cardioversion, the right atrial pressure declined to a greater degree. These findings indicated a disproportionate effect of AF on right atrial pressure. This difference was noteworthy given the long-standing clinical observation that dogs with MMVD have a higher prevalence of right-sided CHF when AF is present. Key clinical message: A dog with MMVD had a greater reduction in right atrial pressure than in left atrial pressure when its AF was cardioverted as part of a cardiac catheterization procedure. This observation proposed a mechanism for the well-known but unexplained observation that dogs with MMVD manifest right-sided CHF disproportionately more often when they have AF.


Effets de la fibrillation auriculaire aiguë et de la cardioversion sur les pressions auriculaires gauche et droite chez un chien. La présence d'une insuffisance cardiaque congestive du côté droit (ICC) chez les chiens atteints d'une cardiopathie du côté gauche est bien connue, mais ses mécanismes ne sont pas complètement compris. Un chien maltais de 12 ans a été admis à la clinique pour une décompression auriculaire gauche afin de traiter une ICC récurrente due à une grave maladie myxomateuse de la valvule mitrale (MMVD). La décompression auriculaire gauche a réussi, mais une fibrillation auriculaire (FA) s'est produite pendant la procédure. La cardioversion électrique a rétabli le rythme sinusal normal (NSR) et la récupération du chien s'est déroulée sans incident. Cette séquence d'événements a permis d'étudier les pressions individuellement dans chaque oreillette chez un chien atteint de MMVD d'origine naturelle pendant la FA et à nouveau pendant la NSR. Bien que les pressions dans les deux oreillettes aient diminué après la cardioversion, la pression de l'oreillette droite a diminué dans une plus grande mesure. Ces résultats ont indiqué un effet disproportionné de la FA sur la pression auriculaire droite. Cette différence était remarquable compte tenu de l'observation clinique de longue date selon laquelle les chiens atteints de MMVD ont une prévalence plus élevée d'ICC du côté droit en cas de FA.Message clinique clé :Un chien atteint de MMVD présentait une réduction plus importante de la pression auriculaire droite que de la pression auriculaire gauche lorsque sa FA était cardiovertie dans le cadre d'une procédure de cathétérisme cardiaque. Cette observation propose un mécanisme pour l'observation bien connue mais inexpliquée selon laquelle les chiens atteints de MMVD manifestent une ICC du côté droit de manière disproportionnée plus souvent lorsqu'ils souffrent de FA.(Traduit par Dr Serge Messier).


Assuntos
Fibrilação Atrial , Doenças do Cão , Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Cães , Animais , Fibrilação Atrial/veterinária , Fibrilação Atrial/tratamento farmacológico , Cardioversão Elétrica/veterinária , Pressão Atrial , Doenças das Valvas Cardíacas/veterinária , Átrios do Coração , Insuficiência Cardíaca/veterinária , Doenças do Cão/cirurgia